• Users Online: 136
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2021  |  Volume : 13  |  Issue : 4  |  Page : 230-235

To review the effect of tightened and loosened torque on two different implant–Abutment connection designs: A scanning electron microscope study


1 Department of Prosthodontics, Crown, Bridge and Implantology, Sudha Rustagi College of Dental Sciences and Research, Faridabad, India
2 Pandit Bhagwat Dayal Sharma University of Health Sciences, Rohtak, Haryana, India

Correspondence Address:
Jyoti Arneja
Department of Prosthodontics, Crown, Bridge and Implantology, Sudha Rustagi College of Dental Sciences and Research, Faridabad, Haryana
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/IJDS.IJDS_222_20

Rights and Permissions

Introduction: It is crucial to take care of stability between various implant parts for the general success rate of the reconstruction. Component fit, saliva contamination, machining accuracy, and screw preload influence the steadiness of implant–abutment connection. Loosening of abutment screws has been a well-known technical problem. Aim: The aim of this study was to gauge repeated tightening and loosening torque on two commercially available implant/abutment connection designs. Study Design: This was an in vitro study. Methodology: A total of 32 implant analogs samples using a metal die with, metal ring of 20mm x 20mm x 20mm in size and a hole in the center were prepared. For both the groups, the implant analog was axially threaded within bases. They were clasped at an edge parallel to the standard minimal bone position. A 35 N/cm torque was enforced, each implant and abutment connection in both the groups using toque ratchet. After 20 min, screws were loosened and detorque measurement was recorded up to ten times. Scanning electron microscope micrographs of selected screws also are presented. SPSS (21.0 version) was used for analyzing data. Results: The mean residual torque for Group 1 was − 51.45 and Group 2 was − 43.29. The RTq (%) was found to be significantly less (0.028*) among Group 2: conical connection as compared to Group 1: butt joint connection. Conclusion: The loosening torque was significantly less in conical connection as compared to butt joint connection.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed265    
    Printed0    
    Emailed0    
    PDF Downloaded42    
    Comments [Add]    

Recommend this journal