Context: Edentulous patients often complain about the instability of mandibular denture. To overcome that, implant-supported overdentures (IODs) have been applied as a good prosthetic option. Aims: The current study compared the changes in retentive force and patterns of surface wear of nylon rings of two stud attachments (ball and locator) upon cyclic loading. Subjects and Methods: Two implant analogs were fixed parallel to each other, 22 mm apart, in custom-made rectangular blocks for each attachment system. Ten nylon inserts of each attachment system were tested. Universal testing machine was used to measure the retentive force, and a low-value fatigue testing machine was used for cyclic loading of 2500 insertion–removal cycles. Surface changes of the components were evaluated by scanning electron microscope (SEM). Statistical Analysis Used: Paired Student's t-test was used to determine groups that were statistically significant. Results: The greatest retention loss rate, i.e., the difference between the initial retentive force and final retentive force was observed in the ball attachment (6.20 N) followed by locator attachment (3.70 N). The results were found to be statistically significant (d ≤ 0.001**). Upon SEM analysis, the nylon inserts of ball attachment revealed more surface wear compared to that of locator attachment. Conclusions: For greater retention and longer function, locator overdenture attachment should be preferred for implant overdentures over ball attachment.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed145    
    Printed5    
    Emailed0    
    PDF Downloaded51    
    Comments [Add]    

Recommend this journal