ORIGINAL ARTICLE
Year : 2018  |  Volume : 10  |  Issue : 4  |  Page : 203-208

Effect of occlusal contact of the loading rod tip on the fracture strength of ceramic crowns


1 Department of Prosthodontics, University of Itauna Dental School, Itauna, MG, Brazil
2 Department of Restorative Dentistry, Piracicaba Dental School, State University of Campinas, Piracicaba, SP, Brazil
3 Departments of Prosthodontics and Periodontology, Piracicaba Dental School, State University of Campinas, Piracicaba, SP, Brazil

Correspondence Address:
Rafael L X. Consani
Department of Prosthodontics and Periodontology, Piracicaba Dental School, State University of Campinas, 901 Limeira Ave., 13414-903 Piracicaba, SP
Brazil
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/IJDS.IJDS_66_18

Rights and Permissions

Aim: The aim of this study was to verify the effect of the occlusal contact of the rod tip on the fracture strength of crowns made with different ceramic systems. Materials and Methods: Conical preparation was performed on bovine teeth with diamond burs in mechanical lathe, and crowns were made for all-ceramic, metal-ceramic, In Ceram, and IPS Empress 2 ceramic systems according to manufacturers' instructions in prosthetic laboratory. The crowns were fixed with resin-modified glass ionomer cement or dual-curing composite resin under a static load of 4 kg for 1 min. To simulate the clinical contact between loading and ceramic crowns, the rod tip was made in accordance with the occlusal form of the ceramic crown. After storage in distilled water at 37°C for 24 h, the samples were submitted to 60,000 mechanical cycles at a load of 35 N/2 Hz immersed in distilled water. The fracture strength test was performed in an Instron with a cross-speed of 0.5 mm/min. Results: Data submitted to one-way ANOVA for randomized experiments followed by Tukey's test (α = 0.05) showed greater value for IPS Empress 2 (208.12 kgf) with significant difference in relation to all-ceramic (149.32 kgf) and In Ceram (142.25 kgf), whereas metal-ceramic showed intermediary value (182.83 kgf). Conclusion: The loading of the rod tip in occlusal contact with the crown did not promote premature failures during the mechanical fatigue test, and two-ceramic systems showed different values of fracture strength after mechanical fatigue test, with better performance for crowns manufactured with IPS Empress 2.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed86    
    Printed6    
    Emailed0    
    PDF Downloaded19    
    Comments [Add]    

Recommend this journal