• Users Online: 1650
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2018  |  Volume : 10  |  Issue : 3  |  Page : 133-138

A comparative evaluation of bite force as a parameter for the stability in conventional and three-dimensional mini plates


1 Department of Oral and Maxillofacial Surgery, Genesis Institute of Dental Sciences and Research, Ferozepur, Punjab, India
2 Department of Prosthodontics, Genesis Institute of Dental Sciences and Research, Ferozepur, Punjab, India
3 Department of Prosthodontics, Dental College Azamgarh, Uttar Pradesh, India

Correspondence Address:
Dr Hemlata Dwivedi
Joy Dental Care and Implant Centre, Near Sharda Chauraha, Rahul Nagar Madaya, Azamgarh - 276 001, Uttar Pradesh
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/IJDS.IJDS_106_17

Rights and Permissions

Introduction: Maxillofacial skeleton fractures can be treated by open (surgical) and closed (non-surgical) techniques. Fracture sites are immobilized either with intermaxillary fixation or external or internal devices (i.e. plates and screws) to allow bone healing. Aim: The study was primarily aimed at investigating the comparison between three-dimensional (3D) mini plates versus conventional mini plates in mandibular fractures under functional load. Methodology: This study was carried out in twenty patients for treatment of mandibular fractures. Bite force readings were made using indigenous bite force recorder in kilograms. Bite forces were recorded at the operated site and contralateral site of the same region. Bite force recordings were done preoperatively before fixing Erich arch bar and postoperatively at each follow-up (7th, 14th, 21st, 28th, and 90th day). Observations: Data show postoperatively in operated sites of the molar that patients in Group A generate more biting force on day 28 and day 90 when compared to Group B. The difference in mean bite force over control group on fractured sites of molars and incisors when comparison was done between postoperative days interval was significant. Conclusion: It was concluded that the 3D mini plates in mandibular fractures are efficacious enough to bear masticatory loads during the osteosynthesis of fracture. It gives the advantage of reduced implant material and 3D stability with almost similar results as seen in two conventional mini plates osteosynthesis.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed3651    
    Printed174    
    Emailed0    
    PDF Downloaded427    
    Comments [Add]    

Recommend this journal