• Users Online: 202
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2017  |  Volume : 9  |  Issue : 3  |  Page : 189-193

Comparative evaluation of shear bond strength of two adhesive systems before and after contamination with oral fluids: An In vitro study


Department of Pedodontics, Himachal Institute of Dental Sciences, Paonta Sahib, Himachal Pradesh, India

Correspondence Address:
Nupur Kesar
Department of Pedodontics, Himachal Institute of Dental Sciences, Poanta Sahib-173025, Himachal Pradesh
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/IJDS.IJDS_29_17

Rights and Permissions

Aim: This study aims to evaluate the effect of saliva and blood contamination on the shear bond strength (SBS) of self- and total-etch adhesive systems on enamel and dentin. Materials and Methods: Sample of 100 extracted noncarious primary molars were taken as experimental groups, which were divided into two groups: self-etch group and total-etch group containing fifty teeth each. These groups were further divided into five subgroups - 10 teeth each. The specimens were then subjected to contamination with saliva or blood; before and after application of adhesive agent, whereas, in control group, there was no contamination done before and after adhesive application. Fresh saliva and blood were used. After the bonding procedure, resin composite was built up with diameter and height of 3 mm. After that, the specimens were tested for SBS in universal testing machine at a crosshead speed of 1 cm/min. The results were then statistically analyzed using one-way ANOVA. Results: The results of the study revealed that the SBS of self-etch adhesive system was better than the total-etch adhesive system and there was significant difference found among various subgroups of total-etch group, i.e., when adhesive application was done before, after and without saliva or blood contamination. There was no significant difference found within the subgroups of self-etch group when adhesive application was done before, after, and without saliva contamination. In case of blood contamination, significant difference was found in SBS in both self- and total-etch groups.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed231    
    Printed19    
    Emailed0    
    PDF Downloaded43    
    Comments [Add]    

Recommend this journal